How to tell if a waiver application is defensible in an audit

A well-judged derogation can be poorly defended. It all comes down to what the file reveals upon review, months down the line.

    On the day an auditor opens a concession file, the engineer who prepared it is not always there to explain it. The file must speak for itself.

    A concession is often decided quickly, under the pressure of a delivery deadline or a stopped line. The engineer knows the case, knows the precedents, and knows why the deviation is acceptable. The problem arises later, when an auditor, a client, or a newcomer reopens the file and finds only a conclusion. The decision may well have been the right one. It is simply no longer defensible. Four checks help determine, before signing, whether a file will stand up to scrutiny from someone who was not in the room.

    A defensible file can be reviewed without its author

    The simplest test is to imagine the file in the hands of an engineer who has never worked on the programme. Can they understand what happened, why the deviation was accepted, and on what basis? If they have to call someone to fill in the blanks, the file is not defensible, regardless of the quality of the decision.

    First check: the non-conformity is unambiguously described

    Everything stems from the notification sheet. The part number, batch, relevant characteristic, measured value, and specified value must appear on it, along with a photograph or survey where available. A description such as "dimension out of tolerance, see photo" is not sufficient if the photograph is not attached or if it is no longer clear which dimension is referred to. Many declaration sheets arrive incomplete. The right time to spot this is before the analysis, not during the audit.

    Second check: the decision relies on identified precedents

    When a concession is granted, it is often because a comparable case has already been accepted without consequence. This reasoning is sound, provided the precedent is cited with its reference number, date, and what makes it comparable. "We have already accepted this before" is not an audit-ready argument. "Concession of 12 March 2023 on the same part number, deviation of the same nature, favourable calculation report" is. The file must also state whether unfavourable precedents exist, and why they do not apply.

    Third check: every justification refers to a source

    A concession file contains technical assertions: the deviation does not affect mechanical strength, the area is non-functional, the safety margin remains sufficient. Each must be traceable to a document, whether a calculation note, a drawing, a customer specification, or an engineering design opinion. A justification without a source relies on the memory of the person who wrote it, and that memory leaves with them.

    The quickest way to verify this point is to re-read the file while highlighting each assertion, then check for the reference supporting it. Those left without a reference are precisely the ones an auditor will question.

    Fourth check: the limits are stated in writing

    A robust file also states what is not known. A piece of data could not be retrieved, an assumption has not been verified, the concession applies only to this batch. These limitations do not weaken the file; they protect it. They demonstrate that the decision was made with full knowledge of the facts, and they prevent a precedent from later being applied beyond what it genuinely covered. A concession granted "for this batch only" and cited two years later as a general rule is among the non-conformities most easily flagged by auditors.

    How AI changes the game by preparing the file with its sources

    These four checks take time, which is often in short supply as concessions pile up during ramp-up. An AI grounded in historical records can take on a significant part of the burden. As soon as the sheet is received, it flags missing information. It locates precedents, both favourable and unfavourable, citing them alongside their references. It produces a draft file in the company's template, where each justification links back to the source document.

    The engineer reviews, corrects, supplements, and signs off. The decision remains theirs, but they are no longer starting from a blank page and no longer have to reconstruct the sources of their rationale from memory. The file they approve is one an auditor can review, step by step.

    A good concession file is not defined by its conclusion. It is defined by what can be verified upon reading it.

    Continue reading

    The latest innovations in Industry 4.0

    Yxir application screen with notification of similar non-conformities detection, illustrating the platform's added value

    Discover Yxir in action on your challenges

    Book a personalised demo and discover how our platform built for industry reduces your non-conformances, accelerates your resolutions, and improves your performance indicators.

    Discover Yxir in action on your challenges

    Book a personalised demo and discover how our platform built for industry reduces your non-conformances, accelerates your resolutions, and improves your performance indicators.

    Discover Yxir in action on your challenges

    Book a personalised demo and discover how our platform built for industry reduces your non-conformances, accelerates your resolutions, and improves your performance indicators.